HETTCUBE 200 | 200 R
INCUBATORS AND COOLED INCUBATORS
Environmentally friendly, economical and well designed. The HettCube range of incubators will benefit balance your sheet and the environment, as well as providing optimum growth conditions for your cultures. The HettCube 200 is ideal for all clinical lab applications.
This unit is also available with refrigeration and a temperature range from 0 °C to +65 °C (HettCube 200 R).

FACTS & NUMBERS
INTERNAL VOLUME:
150 l
VALIDATED USUABLE SPACE:
82 l
NUMBER OF PROVIDED TRAYS:
2 (Standard + 1 HTS)
ENERGY CONSUMPTION:
0.045 kWh/h
DIMENSIONS (W x D x H):
710 x 825 x 970 mm
CAT. NO.: 61201-10 | 61201-11
CAT. NO.: 61201-20 | 61201-21
FIELDS OF APPLICATION
- CLINICAL MICROBIOLOGY, CLINICAL MONITORINGClinical specimen taken from patients or obtained in the course of hygienic monitoring of hospitals are incubated to identify bacteria, fungi, and yeast.
INDUSTRY AND RESEARCH
In many fields microbiological examination is required. Food has to be monitored as well as drinking water or water from waterbodies. Cosmetic products have to be monitored, too. In research labs bacteria are grown for genetic tests or tests in molecular biology.
FACILITIES
- Microbiological labs
- Hospital labs
- Pharmaceutical labs
- Food analyzing labs
- Scientific labs in universities
- Cosmetic industry
- Food and beverage
- Agricultural industry
- Life Science
ACCESSORIES

INTERNAL GLASS DOOR
PARAMETERS FOR CONTINUOUS COOLING OPERATION
Hettich offers an alternative operating mode in its cooled incubators for special applications where low temperatures below 15°C are required over long periods. This ensures high temperature homogeneity and temperature stability. At the same time, the unit’s compressor is better protected, which contributes to a longer service life of the unit and a reduction in energy consumption. Temperatures between +1°C and +5°C usually lead to icing of the cooling unit during continuous operation. If the cooling unit is briefly warmed up once a day, ice formation is reliably prevented. For this purpose, a DeFrost program can easily be created by the user with the help of the touch screen.
Example:
1. Unit cools down to the individual temperature of the customer: in this example first segment to +1°C
2. The cooling unit is briefly heated up: in this example second segment to +10°C for the duration of 1 minute
3. The device remains in stand-by mode: in this example third segment for 3 minutes
4. The unit cools down to an intermediate temperature, this must be 2°C above the set temperature: in this example fourth segment 3°C for Duration of 1 minute
Cat. No.: 60526
Packages
DOWNLOADS

ADDITIONAL PRODUCTS
HETTCUBE 200 | 200 R

FACTS & NUMBERS
CAT. NO.: 61201-10 | 61201-11
CAT. NO.: 61201-20 | 61201-21
FIELDS OF APPLICATION
- phòng thí nghiệm vi sinh
- Phòng thí nghiệm phân tích thực phẩm
- Phòng thí nghiệm khoa học trong các trường đại học
- ngành mỹ phẩm
- Đồ ăn và đồ uống
- Ngành nông nghiệp
- Khoa học đời sống
ACCESSORIES

INTERNAL GLASS DOOR
Nếu bạn muốn theo dõi các mẫu cấy của mình mà không bị mất nhiều nhiệt độ, có thể chọn một cửa kính bên trong.
Cat. No.: 60051 (for HettCube 60)
Cat. No.: 60055 (for HettCube 120)
Packages
DOWNLOADS